14 ULTRACONSOLE INSTALLATION AND OPERATIONS MANUAL
Switch Installation Multiple units “RING” topology
A “RING” configuration is usually used when a user needs access to all computers from different KVM stations. In a
“RING” configuration, a user on any KVM station in the ring can access all the computers in the system. Connect
conflicts can occur with multiple users unless model
UC2-1X16U/E is used for unit #2 or #3. (See Appendix F)
Figure 4. Ring configuration
The Units in Figure 4 can be any UltraConsole model
The “RING” installation procedure is very similar to installing a “BUS” configuration with the exception of removing
jumper JP1 on the expansion cards on two Units and adding an expansion cable from the first Unit to the last Unit.
This additional expansion cable from the first Unit to the last Unit creates the “RING”.
All Units must be equipped with an expansion card. To begin setting up your system in a “RING” configuration,
perform steps 1 13 as outlined in setting up a “BUS” configuration. When doing this, keep in mind that the “OUT”
expansion card connector on the first Unit will be connected with an expansion cable to the “IN” expansion card
connector on the last Unit to complete the “Ring”.
Jumper JP1 must be removed from the expansion cards on two Units in the system to properly maintain cable
termination. To identify which Units must have jumper JP1 removed, calculate the total cable length around the
“RING”. This is from Unit #1’s “IN” connector, around the “RING” and back to Unit #1’s “OUT” connector.
A KVM station on
any Unit can
access all
computers.
JP1
off
JP1
on
JP1
off
Unit #3
CPUs
33 - 48
Unit #2
CPUs
17 32
Unit #1
CPUs
1 16
KVM station
CPU
Cable
KVM
Cable
CPUs
In the example used in Figure 4, removing jumper JP1 on Unit #1
and #3 divides the total ring cable length approximately in half.
Unit #3 (IN) to Unit #1 (OUT) = 20’
Unit #3(OUT) to Unit #2 (IN), Unit #2 (OUT) to Unit #1 (IN) = 20’.