Seite 1 - OPERATIONS MANUAL

10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099

Seite 2 - LIMITED WARRANTY

QUICK SETUP SYSTEM WIRING GUIDE 6 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL The following diagrams offer a basic example of how to connect your

Seite 3 - TABLE of CONTENTS

INSTALLATION CLASSVIEW INSTALLATION AND OPERATINS MANUAL 7 Installing the ClassView Please refer to the safety section prior to installing ClassVie

Seite 4

8 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Step 3. Connecting the bus 3.1 Connect the units together with the coax bus cables by connecting e

Seite 5 - System introduction

CLASSVIEW INSTALLATION AND OPERATINS MANUAL 9 5.2 For example: To view the screen of student #2; Press and release the left control key, hit view

Seite 6 - Features

OPERATION 10 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Operating the ClassView ClassView is simple to operate. Port selection and function comm

Seite 7 - Locating the unit

CLASSVIEW INSTALLATION AND OPERATINS MANUAL 11 Share command The share command is used to interact with a student. The command is issued by press

Seite 8 - FRONT PANEL

12 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Freeze command The freeze command keeps the students screen active but locks their keyboard and mo

Seite 9 - REAR PANEL

CLASSVIEW INSTALLATION AND OPERATINS MANUAL 13 Keyboard timeout command This is a very powerful feature that controls when two or more keyboards a

Seite 10 - CPU Adapter Cable

14 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Minimum / maximum scan port commands The scan minimum and maximum port commands set the range of p

Seite 11 - Installing the ClassView

CLASSVIEW INSTALLATION AND OPERATINS MANUAL 15 Typematic value command ClassView can be configured to control the keyboard typematic rate and dela

Seite 12

LIMITED WARRANTY Copyright  Rose Electronics 1990-2001. All rights reserved. No part of this manual may be reproduced, stored in a retrieval system,

Seite 13

16 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Null command This command is used to re-synchronize an out-of-sync PS/2 mouse. Such a condition

Seite 14 - Operating the ClassView

CLASSVIEW INSTALLATION AND OPERATINS MANUAL 17 Video distance capability The limitation on driving distance is usually due to the quality of the v

Seite 15

18 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Power interruption to the ClassView Certain keyboards are sensitive to rapid cycling of the power.

Seite 16

KEYBOARD COMMAND SUMMARY CLASSVIEW INSTALLATION AND OPERATINS MANUAL 19 Keyboard Command Summary Command Key Sequence Description View [Ctrl] F1

Seite 17

20 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Keyboard command summary (continued) Command Key Sequence Description Keyboard timeout [Ctrl] H x

Seite 18

TROUBLESHOOTING CLASSVIEW INSTALLATION AND OPERATINS MANUAL 21 ClassView troubleshooting guide 1. CPU does not boot, keyboard error received CPU

Seite 19

22 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL 4. Wrong or missing characters from those typed a. The keyboard mode is incorrect. See item 3c a

Seite 20

SERVICE INFORMATION CLASSVIEW INSTALLATION AND OPERATINS MANUAL 23 Maintenance and repair This unit does not contain any internal user-serviceable

Seite 21

SAFETY 24 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Safety This ClassView has been tested for conformance to safety regulations and requirement

Seite 22 - Keyboard commands

CLASSVIEW INSTALLATION AND OPERATINS MANUAL 25 Safety and EMC regulatory statements Safety Information Documentation reference symbol. If the pro

Seite 23 - Keyboard Command Summary

TABLE of CONTENTS Contents Disclaimer ... 1 Sys

Seite 24

APPENDICES26CLASSVIEW INSTALLATION AND OPERATIONS MANUALAppendix A. Cable pinout informationYou can, if you prefer, build your own adapter cables. Th

Seite 25 - TROUBLESHOOTING

CLASSVIEW INSTALLATION AND OPERATINS MANUAL27Pin-to Pin wiringCPU AdapterPS/2 Keyboard port with MiniDin-6FPS/2 Mouse port with MiniDin-6FClassViewDB-

Seite 26

28 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Appendix B. CPU/KB-Monitor-Mouse pinout DB-25 Female Connector Pinouts for ClassView DB-25 Fem

Seite 27 - Technical support

CLASSVIEW INSTALLATION AND OPERATINS MANUAL 29 Appendix C. Factory default settings Setting Default Scan enable Off Scan time Interval 5 seconds

Seite 28

30 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Appendix E. General specifications SIZE / WEIGHT 8.8"W x 2.25"H x 4.9"D / 3 lbs IN

Seite 30 - APPENDICES

10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099

Seite 31 - CPU Adapter

Figures Figure 1. ClassView unit (Front view) ... 1 Figure 2. Front panel, model # CVT-CM

Seite 32

INTRODUCTION CLASSVIEW INSTALLATION AND OPERATINS MANUAL 1 Disclaimer While every precaution has been taken in the preparation of this manual, the

Seite 33 - ADDRESS

2 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Features  Instructor can access any student's computer in three modes:  View mode – See st

Seite 34

GETTING STARTED CLASSVIEW INSTALLATION AND OPERATINS MANUAL 3 To acquaint you with your ClassView unit, this manual first describes ClassView'

Seite 35

FRONT PANEL 4 CLASSVIEW INSTALLATION AND OPERATIONS MANUAL Figure 2. Front panel, model # CVT-CMB 1 Address Defines the number of the CPU att

Seite 36

REAR PANEL CLASSVIEW INSTALLATION AND OPERATINS MANUAL 5 Figure 3. Rear panel, model #CVT-CMB 1 BUS in/ BUS out Bus cable to next unit or ter

Kommentare zu diesen Handbüchern

Keine Kommentare